Process
Date: June 2001

The flashing was removed from
this plastic medical device with a Synrad 25-watt laser.
This
part, made of MDPE (Medium Density Polyethylene), was rotated at 300
rpms, while the flashing was removed with 18 watts of laser power and
5psi air assist. The process results in a desirable smooth, rounded
edge, with no loose plastic debris. HDPE, LDPE, and PTFE can also be
cut with the same results. The metal rod was used to form the inside
diameter of the part during production.
|